HEATING
Customer Service 800.304.6563 | HVACCustomerService@robertshaw.com | Robertshaw.com
Universal.replacements/retrofi.ts.for.many.other.brands,.mercury-free.800.Series.line.voltage.thermostats.need.no.leveling.or.special.disposal..
They.feature.bimetal.temperature.sensing.and.are.accurate.to.within.+/-2 F..J-Box.compatible,.these.units.meet.code.and.install.quickly.
9200.Series.Deluxe.Mechanical.thermostats.replace.more.than.50.competitive.models.and.potentially.minimize.inventory.space..
Also,.with.no.sub-base.or.leveling.required.and.a.simple.base.and.cover.design,.they.install.quickly..Horizontal.and.vertical.designs.are.available.
WALL THERMOSTATS
RS1000 Series Economy Digital
RS1000.Economy.Series.battery.powered.manual/5-1-1.programmable.thermostats.are.designed.as.aff.ordable.options.in.
new.or.replacement.residential.applications..They.can.be.confi.gured.to.control.conventional.gas.or.electric.HVAC,.heat.
pump,.oil.and.millivolt.equipment.in.either.Fahrenheit.or.Celsius..They.off.er.control.accuracy.of.+/-1°F.@.68°F.(0.5°C.@.20°C).
Part
Number
Description
Heat/Cool
Confi guration
Power
Source
Temperature
Control Range
Relay Contact
Voltage
Relay Contact
Current
Dimensions
Control Features
Terminations
RS1110
Economy Battery
Operated Manual/
Programmable
Thermostat
4-wire
1 Heat/1 Cool
Conventional
Gas/Electric
or Heat Pump
3V DC
(2 x AAA
Alkaline
Batteries)
Heating:
40° to 90°F
(5° to 32°C)
in 1° Steps
Cooling:
60° to 95°F
(16° to 35°C)
in 1° Steps
24V AC / 50/60 Hz 1 Amp Maximum
(Inductive)
3.35" H x 4.5" W
x 1" D
(85mm H x 114mm W
x 26mm D)
Manual or 5-1-1 Programmable
Fahrenheit or Celsius
Adjustable Temperature Differential
Compressor Short-Cycling Protection
Worry-Free Memory Retention for
Power Outages
R – 24V
Switching Voltage
G – Fan, W – Heat
or O/B O – rev.
Valve in Cooling
B – Rev. Valve
in Heating
HUMIDISTATS AND DEHUMIDISTATS
J10 Series
Ranco®.J10.Series.Humidistats.and.Dehumidistats.regulate.relative.humidity.in.confi.ned.spaces.by.cycling.centralized.humidifying.or.dehumidifying.systems..The.
nylon.sensing.element.provides.fast.response.time,.accurate.control.and.long.life.
Part Number
Description
Humidity Range
Electrical Rating
Temperature Range
Differential
J10-808
Humidistat – Wall or Duct Mount
10% to 60% Relative Humidity
24V AC/60V AC
Switch Head 32°F to 140°F
(0°C to 60°C)
5% or 15% RH
J10-809W
Dehumidistat – Wall Mount
20% to 80% Relative Humidity
24V AC/60V AC
Switch Head 32°F to 140°F
(0°C to 60°C)
5% or 15% RH
J10-810
Dehumidistat – Wall Mount
(Vertical)
20% to 80% Relative Humidity
24V AC/60V AC
Switch Head 32°F to 140°F
(0°C to 60°C)
5% or 15% RH
J10-821
Humidistat – Wall Mount
(Horizontal)
20% to 80% Relative Humidity
24V AC/60V AC
Switch Head 32°F to 140°F
(0°C to 60°C)